Heat And Thermodynamics Ques 16

  1. A water cooler of storage capacity 120 litres can cool water at a constant rate of $P$ watts. In a closed circulation system (as shown schematically in the figure), the water from the cooler is used to cool an external device that generates constantly $3 kW$ of heat (thermal load). The temperature of water fed into the device cannot exceed $30^{\circ} C$ and the entire stored 120 litres of water is initially cooled to $10^{\circ} C$. The entire system is thermally insulated. The minimum value of $P$ (in watts) for which the device can be operated for 3 hours is

(2016 Adv.)

(Specific heat of water is $4.2 kJ kg^{-1} K^{-1}$ and the density of water is $1000 kg m^{-3}$ )

(a) 1600

(b) 2067

(c) 2533

(d) 3933

Show Answer

Answer:

Correct Answer: 16.(b)

Solution:

Formula:

Calorimetry :

  1. Heat generated in device in $3 h$

$$ =\text { time } \times \text { power }=3 \times 3600 \times 3 \times 10^{3}=324 \times 10^{5} J $$

Heat used to heat water

$$ =m s \Delta \theta=120 \times 1 \times 4.2 \times 10^{3} \times 20 J $$

Heat absorbed by coolant

$$ \begin{aligned} & =P t=324 \times 10^{5}-120 \times 1 \times 4.2 \times 10^{3} \times 20 J \\ P t & =(325-100.8) \times 10^{5} J \\ P & =\frac{223.2 \times 10^{8}}{3600}=2067 W \end{aligned} $$



Table of Contents

sathee Ask SATHEE

Welcome to SATHEE !
Select from 'Menu' to explore our services, or ask SATHEE to get started. Let's embark on this journey of growth together! 🌐📚🚀🎓

I'm relatively new and can sometimes make mistakes.
If you notice any error, such as an incorrect solution, please use the thumbs down icon to aid my learning.
To begin your journey now, click on

Please select your preferred language
कृपया अपनी पसंदीदा भाषा चुनें